Name Description
RecurringOffset Specifies the time in minutes by which you want to
change the time when recurring daylight savings
begins and ends. The offset is added to the current
time when daylight savings time begins and
subtracted from the current time when daylight
savings time ends.
Rear ports mode configuration
Use the procedures in this section to display and configure the rear ports operational mode for a
standalone switch or a stack.
Configuring the rear ports mode
Use this procedure to display and configure the rear ports operational mode for a standalone switch
or a stack.
Procedure
1. From the Device Physical View, select a unit.
2. In the navigation tree, double-click Edit.
3. From the Edit tree, click Unit.
4. In the work area, select the Rear Ports Mode tab.
5. In the RearPortAdminMode section, click a radio button.
Important:
A switch restart is required in order for the operational mode to take effect.
Rear Ports Mode field descriptions
The following table describes the fields on the Rear Ports Mode tab.
Name
Description
RearPortAdminMode Specifies the rear ports operational mode. Values
include:
• standalone: selects the standalone operational
mode for the rear ports
• stacking: selects the stacking operational mode
for the rear port
DEFAULT: standalone
RearPortOperMode Displays the configured operational mode of the rear
ports.
Configuring the switch using EDM
July 2015 Getting Started with Avaya ERS 3500 Series 137
Comments on this document? infodev@avaya.com