52 XR Series Installation Instructions
12 Troubleshooting & Error Messages
12 Troubleshooting & Error Messages
Problem Cause and/or Probable Solution
Unit won’t power up: Verify AC power source (Outlets, breakers, etc.)
Check terminal block connections inside the main
enclosure.
Verify power wiring from terminal block to the power
supply board.
Check fuse on power supply board and controller
board.
Unit has power, but there is
no display.
Verify ribbon cable connections from controller board
to the display board.
Check 12V light and fuse on controller board.
If the unit is in COMMAND mode, the display will
remain blank until data is received.
Dashes across the display. Communications have failed.
Verify the correct terminal (RS 232, 422/485, 20 mA)
is being used and check wiring.
Verify cable or radio connection to indicator.
Verify indicator serial port function
Display reads “Err 1”. Baud Rate Auto-Learn has failed.
Verify the correct terminal (RS 232, 422/485, 20 mA)
is being used and check wiring.
Verify cable to indicator.
Verify that data is being transmitted to the XR from
the indicator and that the data string contains numeric
characters.
Display reads “Err 2”. Data String Auto-Learn has failed or Radio not
receiving.
Verify the correct terminal (RS 232, 422/485, 20 mA)
is being used and check wiring.
Verify cable or radio connection to indicator.
Verify that a data string is being sent to the XR from
the indicator and that the data string contains either
an STX character (ASCII 02) or a CR character
(ASCII 13).
Display reads “Err 3”. The XR is receiving data on multiple communications
ports.
STATUS light NOT blinking
(OFF)
Verify that unit has power. When powered, if the
Status light remains OFF, the processor is not
running.
STATUS light blinking fast
(3/second) for longer than
30 seconds:
The XR is not able to Auto-Learn the data string or
baud rate. See Error Messages “Err 1” and Err 2”.
RS232 light not flashing Verify the RS232 terminal is being used and check
communications wiring at the indicator.
Verify that data is being sent to the XR from the
indicator and that the data string contains numeric
characters.

Table of Contents

Other manuals for Avery Weigh-Tronix XR 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix XR 2000 and is the answer not in the manual?

Avery Weigh-Tronix XR 2000 Specifications

General IconGeneral
BrandAvery Weigh-Tronix
ModelXR 2000
CategoryMonitor
LanguageEnglish

Related product manuals