Abnormal Procedures 5-15
NO COMMUNICATION WITH AUTOPILOT
Failure Indication:
If the PFD stops receiving data from the autopilot, a yellow “NO
COMMUNICATION WITH AUTOPILOT” message is displayed in
the center of the PFD annunciator strip.
Functionality Lost:
All autopilot functionality will be lost for the duration of this
message display. It is possible that the autopilot will conduct an
auto-reset which would kick off any engaged autopilot mode but
following a successful reset, all functionality would be restored
and a manual re-command of autopilot modes will be available.
Recommended Pilot Action:
Immediately transition to hand-flying via the PFD display.
If the autopilot does not conduct a successful automatic restart,
consider attempting an autopilot restart by cycling the autopilot
circuit breaker.