Operation instructions | EOC 1-32 and EOC 2-32 | Ethernet over Coax Peer to Peer
14 2021-06-23 | Technical improvements, changes in design, printing- and other errors reserved.
4.2. Internet from telephone operator
4.2.1. Amplifier with switchable return path
The IP data from the telephone provider is received by a router and forwarded to an EOC 1-32. The feeding of
the IP signal into the TV distribution network takes place via a return path suitable antenna wall outlet.
Important: A high-pass filter TZU 19-68X must be installed in the coaxial feed line at the amplifier
output. In addition, the return path of the amplifier must be switched off. Otherwise it may cause
interferences in the cable network.
Connection to a multimedia antenna wall outlet BSD 963-14N:
The EOC's G.hn connectors are connected to the DATA connector of
the antenna wall outlet. TV devices are connected to the TV
connector of the EOC.
Connection to a CATV antenna wall outlet
BSD 21-14N: The G.hn connector of the EOC is
connected to the TV connector of the antenna wall
outlet. A TV device is connected to the TV socket of
the EOC.

Table of Contents

Other manuals for axing EoC 1-01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the axing EoC 1-01 and is the answer not in the manual?

axing EoC 1-01 Specifications

General IconGeneral
Brandaxing
ModelEoC 1-01
CategoryModem
LanguageEnglish

Related product manuals