    Debra PorterAug 10, 2025
    What to do if the axing OTX 1310-10 laser power of the optical transmitter and receiver are normal, but there is no RF output signal at the receiver or the output level is too low?
    • K
      kellychangAug 10, 2025
      If the laser power of the axing optical transmitter and receiver are normal, but there is no RF output signal at the receiver or the output level is too low, it could be due to no input RF signal or a poor RF connection. You should check the RF level and reconnect the RF input.
  • J
    James CooperAug 20, 2025
    What to do if the axing OTX 1310-10 Transmitter LED does not work?
    • K
      Kimberly HollandAug 20, 2025
      If the LED on your axing Transmitter does not work, it could be due to a lack of electrical power or a blown fuse. Ensure the power is ON, or replace the fuse.
  • C
    Chad KimAug 30, 2025
    What to do if the axing OTX 1310-10 LED displays the status is normal, but there is no laser output or the output does not match the display?
    • S
      Steven HamiltonAug 30, 2025
      If the LED displays a normal status, but there is no laser output or the output doesn't match the display, the output laser power measurement might be incorrect, the ring flange or test jumper connection could be dirty, or the test jumper connection might mismatch. Try changing the output laser power sensor, cleaning the connection, or changing the test jumper.