AXIS 240Q - Troubleshooting
Emergency Recovery Procedure
If power or the network connection to the AXIS 240Q is lost during the upgrade, the
process will fail and the unit will become unresponsive. A flashing red Status LED indicates
a failed upgrade. To recover the unit, follow the steps below. The serial number is found on
the underside label on the product casing.
1. Unix/Linux - From the command line, type the following:
arp -s <IP address of AXIS 240Q> <Serial number> temp
ping -s 408 <IP address of AXIS 240Q>
Windows - From a command/DOS prompt, type the following:
arp -s <IP address of AXIS 240Q> <Serial number>
ping -l 408 -t <IP address of AXIS 240Q>
2. If the unit does not reply within a few seconds, restart it and wait for a reply. Press
CTRL+C to stop Ping.
3. Open a browser and type in the AXIS 240Q’s IP address. In the page that appears, use
the Browse button to select the upgrade file to use, e.g. axis240q.bin. Then click the
Load button to restart the upgrade process.
4. After the upgrade has completed (1-10 minutes), the unit will automatically restart and
show a steady green on the Power and Status LED’s and flashing green or amber on the
Network LED.
5. Reinstall the AXIS 240Q. See the Installation Guide.
If the emergency recovery procedure does not get the AXIS 240Q up and running again,
please contact Axis support at www.axis.com/techsup/
Support
If you contact Axis support, please help us help you resolve your problems expediently by
providing a server report, log file and a brief description of the problem.
Server Report - go to Setup > System Options > Support Overview. The server report
contains important information about the server and its software, as well as a list of the
current parameters.
Log file - go to Setup > System Options > Logs & Reports. The Log file records events
within the unit since the last restart of the system and can prove a useful diagnostic tool
for troubleshooting.

Other manuals for Axis 240Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis 240Q and is the answer not in the manual?

Axis 240Q Specifications

General IconGeneral
BrandAxis
Model240Q
CategoryServer
LanguageEnglish

Related product manuals