AboutPTZ(PanTiltZoom)
AboutPTZ(PanTiltZoom)
Aboutpresetpositions
Apresetpositionisasavedviewthatcanbeusedtoquicklysteerthecameratoaspecicposition.Apresetpositionconsistsof
thefollowingvalues:
Panandtiltpositions
Zoomposition
Focusposition(manualorautomatic)
Howtoaccessthepresetpositions
Presetpositionscanbeaccessedinseveralways:
ByselectingthepresetfromthePresetpositionsdrop-downlistintheLiveViewPage.
Whensettingupactionrules.Seepage34.
Howtoaddapresetposition
1.GotoSetup>PTZ>PresetPositions.
2.Clickintheimageorusethecontrolstosteerthecameraviewtothedesiredposition.
3.WriteanameintheCurrentpositioneld.
4.Ifrequired,selectUsecurrentpositionasHome.
5.ClickAddtosavethepresetposition.
Howtoincludethepresetpositionnameinanoverlaytext
1.GotoVideo&Audio.
2.SelectIncludetext.
3.Writethemodier#Pintheeld.
4.ClickSave.
Howtosetthehomeposition
TheHomepositionisreadilyaccessiblebyclickingtheHomebuttonontheliveviewwindowandinthePresetPositionssetupwindow.
Tosetacustomizedhomeposition,selectUsecurrentpositionasHomewhenaddingapresetposition.Theuser-denedhome
positionwillhave(H)added,forexample,Entrance(H).ThedefaultHomeposition,called“Home”,willstillbeavailable.
TheproductcanbeconguredtoreturntotheHomepositionwhenthePTZfunctionalityhasbeeninactiveforaspeciedlength
oftime.EnterthelengthoftimeintheReturntohomewheninactiveeldandclickSave.Setthetimetozerotopreventthe
productfromautomaticallyreturningtotheHomeposition.
OSDIZones
On-ScreenDirectionIndicator(OSDI)zonescanbeincludedintheoverlaytext(seeAboutoverlaytextonpage22)toaidtheuserto
navigatetheAxisproduct.EachOSDIzoneissetupwithcoordinatesandadescriptivename.