AXISQ6052PTZDomeNetworkCamera
Axismulticable
Axismulticable
WhenconnectingexternalequipmenttotheAxisproduct,anAxismulticableisrequiredinordertomaintaintheproduct’sIPrating.
TheAxismulticablecanbepurchasedfromyourAxisreseller.Tolocatethemulti-connector,seeHardwareOverviewonpage7.
Themulticableprovidesthefollowingconnectors:
Powerconnector-3-pinterminalblockusedforpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource
(LPS)witheitheraratedoutputpowerlimitedto100Woraratedoutputcurrentlimitedto5A.
Audioin(pink)-3.5mminputforamonomicrophone,oraline-inmonosignal(leftchannelisusedfromastereosignal).
Audioout(green)-3.5mmoutputforaudio(linelevel)thatcanbeconnectedtoapublicaddress(PA)systemoranactivespeaker
withabuilt-inamplier.Astereoconnectormustbeusedfortheaudioout.
I/Oterminalconnector-Usewithexternaldevicesincombinationwith,forexample,tamperingalarms,motiondetection,event
triggering,timelapserecordingandalarmnotications.Inadditiontothe0VDCreferencepointandpower(DCoutput),theI/O
connectorprovidestheinterfaceto:
DigitaloutputForconnectingexternaldevicessuchasrelaysandLEDs.Connecteddevicescanbeactivatedbythe
VAPIX®ApplicationProgrammingInterface,outputbuttonsontheLiveViewpageorbyanActionRule.Theoutput
willshowasactive(shownunderSystemOptions>Port&Devices>PortStatus)ifthealarmdeviceisactivated.
DigitalinputAnalarminputforconnectingdevicesthatcantogglebetweenanopenandclosedcircuit,for
example:PIRs,door/windowcontacts,glassbreakdetectors,etc.Whenasignalisreceivedthestatechangesand
theinputbecomesactive(shownunderSystemOptions>Port&Devices>PortStatus).
FunctionPinNotes
Specications
0VDC(-)
1
DCoutput
2
Canbeusedtopowerauxiliaryequipment.
Note:Thispincanonlybeusedaspowerout.
3.3VDC
Maxload=250mA
DigitalinputConnecttopin1toactivate,orleave
oating(unconnected)todeactivate.
0tomax40VDC
Congurable(Input
orOutput)
3–6
DigitaloutputConnectedtopin1whenactivated,
oating(unconnected)whendeactivated.Ifusedwith
aninductiveload,e.g.arelay,adiodemustbeconnected
inparallelwiththeload,forprotectionagainstvoltage
transients.
0tomax40VDC,open
drain,100mA
Foranexamplediagram,seeConnectionDiagramsonpage71.
I/Oconnector