AXIST8341PIRMotionSensor
Z-Waveconfiguration
Z-Waveconfiguration
ThefollowinginformationisforpersonswithexperienceofsettingupaZ-Wavesystem,orforsomeonethathascomputersoftware
runningaZ-Wavecontroller.PleasefamiliarizeyourselfwiththeZ-Wavecontroller’ssoftwarebeforegettingstarted.
Tominimizebatterypowerconsumption,RFonthedeviceisswitchedoffbydefault.Inordertostartthesetupprocess,pressthe
tamperswitchoncetoturnontheRFpowerfor30seconds.YouwillthenseetheLEDstarttoblinkonceasecond.Ifsetupisnot
completedwithin30seconds,pressthetamperswitchoncemoretocontinue.
Basicsetlevel
WhenaBasicSetCommandissentandcontainsavalue,thereceiverwillprocessit.Forexample,alampmodulewould
receiveaBasicSetcommandthatdeterminesthedimlevel.
Example:
1-99:ON(BinarySwitchDevice)
DimLevel(MultilevelSwitchDevice)
FunctionParameternumber
Size
Range
Default
BasicSetlevel
11
1~9999
Sensitivitylevel(PIRsensoronly)
Foroptimalefciency,itisrecommendedtotestthedetector’sresponsetomovementsatthefarthestreachofthe
coverageareawhenyouuseitforthersttime.Ifmovementscannotbedetectedaccurately,simplyadjustthesensitivity
levelwiththeCongurationParameter#3.Thisparametercanbeconguredfrom1to10,where1islowsensitivity
and10isthehighestsensitivity.
FunctionParameternumber
Size
Range
Default
Sensitivitylevel
3
1
1~106
Re-triggerintervalsetting(PIRsensoronly)
Thecongurationparameterusedtoadjustthere-triggerintervalafterthedetectorhasbeentriggeredasconguration
parameter#4.Noresponsewillbemadeduringthisintervalifmovementisdetected.Thetimeintervalcanbeset
from5to3600seconds.
FunctionParameternumber
Size
Range
Default
Re-triggerinterval
4
2
5~3600(sec)
180
Luxlevel
Youcansetapercentagefortheluxlevel,whichdetermineswhenthelightsensorwillbeactivated.Iftheambient
illuminationdropsbelowthesetpercentage,andapersonmovesacrossorwithintheprotectedarea,thedetectorwill
sendaZ-WaveONcommand(i.e.BasicSetcommand(Value=BasicSetLevel))tothecontrollerandactivateconnected
modulesandlighting.Thepercentagecanbesetfrom1%to100%.
FunctionParameternumber
Size
Range
Default
Luxlevel
51
1~100%20
On-offduration
Theon-offdurationsettingcanbeusefulifthedetectorisconnectedtoamoduleorlighting.Thedurationdetermineshowlongthe
module/lightingshouldstayON.Forexample,alampmoduleturnsoff100secondsafterithasbeenturnedon.Thedurationcanbe
conguredtolast5to3600seconds.
10