EasyManua.ls Logo

Axor Microspeed 12 - Microspeed Peak Current Adjustment; Microspeed Offset Adjustment

Axor Microspeed 12
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MICROSPEED
28
REV 04/05
To reduce the value of peak current,its necessary to
mount RIP on the socket (see fig. 1) located inside of
the drive.
Below is a table with the proper values:
current express in (A).
RIP Value
in Kohm
*22015082685647393322
MCS 1/2 (A)
2 1.9 1.8 1.65 1.6 1.5 1.4 1.35 1.3 1
MCS 2.5/5 (A)
5 4.6 4.5 4.1 3.9 3.7 3.5 3.4 3.1 2.6
MCS 6/12 (A)
12 11.1 10.7 9.7 9.3 8.9 8.4 8 7.5 6
MCS 10/20 (A) 20 18 17.4 15.5 15 14.4 13.7 13 12.1 10
The drive is provided with the offset adjustment made
by tachogenerator feedback.
If any further adjustment is required,please use the Bil
potentiometer .
(The compensation is +/- 200mV in respect to the
input reference).
With zero input reference adjust the potentiometer until
the motor is perfectly still.
6.3 Peak current adjustment
6.4 Offset adjustment