4
Model Numbers
Model Numbers
D04 Filter-Regulator,
or D14 Regulator
Pressure Switch
Oil Drip Monitor
or
Oil Feed Monitor
Models w/o
Electrical Control
Circuit
Models w/
Electrical Control
Circuit
Operating
Pressure
Check
Manifold
Pressure
Check
MC9-01L3-B02
MC9-01L3-3B15
Nil
Attached
Nil
Nil
MC9-01L3-B03
MC9-01L3-3B16
Nil
Attached
attached
Nil
MC9-01L3-D02
MC9-01L3-3D15
with D04 attached
Attached
Nil
Nil
MC9-01L3-D03
MC9-01L3-3D16
with D04 attached
Attached
attached
Nil
MC9-01L3-D22
MC9-01L3-3D35
with D04 attached
Attached
Nil
with Oil Drip Monitor
MC9-01L3-D23
MC9-01L3-3D36
with D04 attached
Attached
attached
with Oil Drip Monitor
MC9-01L3-DA2
MC9-01L3-3DC5
with D04 attached
Attached
Nil
with Oil Feed Monitor
MC9-01L3-DA3
MC9-01L3-3DC6
with D04 attached
Attached
attached
with Oil Feed Monitor
MC9-01L3-H22
MC9-01L3-3H35
with D14 attached
Attached
Nil
with Oil Drip Monitor
MC9-01L3-H23
MC9-01L3-3H36
with D14 attached
Attached
attached
with Oil Drip Monitor
MC9-01L3-HA2
MC9-01L3-3HC5
with D14 attached
Attached
Nil
with Oil Feed Monitor
MC9-01L3-HA3
MC9-01L3-3HC6
with D14 attached
Attached
attached
with Oil Feed Monitor
MC9-01L3-3T08
***
Nil
attached
(PNP type)
Nil
Nil
Note:
1. Pressure gauge for operating pressure is attached on the MC9 models equipped with
D04 (Filter-Regulator integrated solenoid valve), and on the MC9 models equipped with
D14 (Regulator integrated solenoid valve).
2. Manifold pressure gauge and oil level switch are standard equipped items.
3.
CAUTION
Twin timer or programmable controller should be prepared in advance separately
for the interval oil shot operation of the pump in the Micron-Lub lubrication unit.
(MC9 models with electrical control circuit are excepted)
User side must make electrical control circuit for the Micron-Lub lubrication system.
4. Filter-Regulator with solenoid valve have no function to remove moisture and gaseous oil
contained in supply air. (This is 3:-:- of compressed air quality classification). Installations of air
preparation equipment that satisfy the Micron-Lub lubrication system are required. We Azbil TA
are dealing in oil removal filters removing gaseous oil, which are recommended to install in air
supply side, for the compressed air quality classification of 1. - 2.