70
Chapter 4 CARAVAN EQUIPMENT
4. If the pressure gauge indicates the same pressure after a period of 10
minutes there are no leaks. If the pressure drops the gas system is
leaking. The gas system should then be inspected and repaired by a
competent person.
Technical Data
Operating pressure 30 mbar
Operating regulator 0.6bar
Reserve regulator 0.3 bar
Rate of flow 1.5kg/h
Product Identification number CE-0085AS0417
AUTOMATIC GAS CHANGE-OVER SYSTEM (continued)