EasyManua.ls Logo

Baker SG403A - Page 30

Default Icon
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document: 333D012G
5-18-2007
- 29 -
3. Slide the new exhaust filter in all the way in until it stops against the rear filter stop. Be careful not to contact
the filter media with your fingers. Align the filter frame, left to right, so it is positioned directly over the exhaust
plenum.
4. Tighten the two (2) ½” hex head exhaust plenum clamping bolts, alternating two or three revolutions at a time
until the filter gasket is compressed approximately 1/8” [3.2mm].
5. Tighten the two (2) ½” hex head down flow plenum clamping bolts, alternating two or three revolutions at a
time until the filter gasket is compressed approximately 1/8” [3.2mm].
6. Reassemble the cabinet following the previous instructions in reverse order.
IMPORTANT
When reinstalling the front seal panel, first tighten each ¼-20 hex cap screw until the bolt seal washer is engaged
with the panel. Next turn each bolt 1 ¼ to 2 ½ revolutions until the panel gasket is evenly compressed
approximately half way. Do not over tighten. Use caution if using a power driven tool.
7. Reconnect power.
8. Check the filter and gasket for leaks.

Table of Contents

Related product manuals