25
ML550, 551, 554
Panel Operation
Cool/Warm
ML500, 551, 554
Press the “Cool” or “Warm button once to display the set
temperature. Each time either button is pressed again, the
set temperature will increase or decrease depending on
which button is pressed. After three seconds, the LCD will
automatically display the last measured spa temperature.
Mode
ML500, 551, 554
This button is used to switch between Standard,
Economy, and Sleep modes. Press “Mode” to enter mode
programming, press Cool” to cycle through to desired
mode (LCD flashes until confirmed), then press Mode” to
confirm selection.
Sleep mode heats the spa to within 11°C (20°F) of the set
temperature only during filter cycles.
will appear on
the display until mode is changed.
Standby Mode
Pressing Cool” or “Warm” followed by Blower or “Jets 2”
or Aux” will turn off all spa functions temporarily. This is
helpful when changing a filter. Pressing any button exits
Standby mode. On some systems the Jets 1” button will
control the pump in Standby Mode (“Drain Mode”). In this
case, press any other button to exit. System will revert to
previous mode after 1 hour.
Jets 1
Press the “Jets 1” button once to turn pump 1 on or off, and
to shift between low and high speeds if equipped. If left
running, the pump will turn off after a time-out period. The
pump 1 low speed time-out on some systems may be as
long as 4 hours.
On non-circ systems, the low speed of pump 1 runs when
the blower or any other pump is on. It may also activate
for at least 1 minute every 30 minutes to detect the spa
temperature (polling) and then to heat to the set temperature
if needed, depending upon mode. When the low speed turns
on automatically, it cannot be deactivated from the panel;
however, the high speed may be started.
Jets 2
(optional on some systems)
Press the “Jets 2” button once to turn pump 2 on or off, and
to shift between low and high speeds if it is a two-speed
pump. If left running, the pump will turn off after a
time-out period.
Please refer to the following User Guides for more detailed information:
ML551/ML554 User Guide: P/N 40632-99
ML 550 User Guide: P/N 40569-99
ML551 ML554
HeatHeat
Warm
Light
Warm
Jets 1
Jets 2
Light
Mode
Cool
Blower
ML550
HeatHeat
Warm
Light
Warm
Jets 1
Jets 2
Light
Mode
Cool
Blower
Heat
Cool Warm Jets 1 Jets 2 Blower Light Mode

Table of Contents

Other manuals for Balboa ML554

Question and Answer IconNeed help?

Do you have a question about the Balboa ML554 and is the answer not in the manual?

Balboa ML554 Specifications

General IconGeneral
BrandBalboa
ModelML554
CategoryControl Panel
LanguageEnglish

Summary

ML550/551/554 Panel Operation

Jets 1 Operation

Controls pump 1 operation and speed settings.

Jets 2 Operation

Controls pump 2 operation and speed settings.

ML550/ML554 Panel Feature Details

Preset Filter Cycle Configuration

Manages automatic filtration cycles for spa maintenance.

Freeze Protection System

Activates pumps/blower to prevent freezing in cold temperatures.

ML200-400 Series Panel Operation

ML200-ML400 Panel Function Details

ML400 Jets Operation

Controls pump 1 operation on ML400 panel.

ML400 Jets 2/Aux Control

Controls pump 2 on ML400 panel using the Aux button.

ML200-ML400 Advanced Features

ML400 Freeze Protection

Protects spa from freezing in cold weather on ML400.

ML400 Filter Cycles

Manages automatic filter cycles on ML400.

GL Series Persistent Memory

Persistent Memory Function

Explains the function and reset procedure for persistent memory.

Memory and Time Retention

Details how settings are stored and how time is maintained.

Power Up Display Sequence

Describes the power-up sequence and display of system information.

VL Series Panel Overview

GS Panel 500 Series Operation

GS Panel 500 Series Functions

GS Panel Jets Operation

Controls spa jets operation, including speed and timeouts.

GS Persistent Memory and VL Panels

Persistent Memory Reset Procedure

Steps to reset the spa's persistent memory.

System Circuit Board Replacement

Circuit Board Removal

Step-by-step guide for removing the spa circuit board.

Circuit Board Installation

Step-by-step guide for installing a new spa circuit board.

Spa Sensor Set Testing

Faulty Sensor Diagnosis

Test sensors in warm water to verify functionality.

Heater Assembly Removal

Heater Removal Steps

Steps to safely remove the heater assembly from the spa system.

Panel Message Reference Guide

Related product manuals