EasyManua.ls Logo

Balluff BSP-V Series - Page 44

Balluff BSP-V Series
80 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 español
Interfaz IO-Link
Datos de parámetros
Index
hex
Subindex
hex
Object name Access Length Value Range Gra-
dient
Unit Default
0x3C 0x01 SetPoint 1 = SP1 R/W 2 bytes Process Data 100%
0x3C 0x02 SetPoint 2 = rP1 R/W 2 bytes Process Data 0%
0x3E 0x01 SetPoint 1 = SP2 R/W 2 bytes Process Data 100%
0x3E 0x02 SetPoint 2 = rP2 R/W 2 bytes Process Data 0%
0x60 0x00 Password W 4 bytes 0000..9999 0
0xD0 0x00 Delay Switching Time 1 R/W 2 bytes 0..500 0.1 sec 0
0xD1 0x00 Delay Back Switching Time 1 R/W 2 bytes 0..500 0.1 sec 0
0xD2 0x00 Delay Switching Time 2 R/W 2 bytes 0..500 0.1 sec 0
0xD3 0x00 Delay Back Switching Time 2 R/W 2 bytes 0..500 0.1 sec 0
0xD5 0x00 Min Pressure Value R 2 bytes Process Data
0xD6 0x00 Max Pressure Value R 2 bytes Process Data
0xD7 0x00 Measure damping R/W 2 bytes 0…1000
in 10 ms steps
1 ms 0
Sensores de presión con IO-Link
BSP-B... /-V...

Related product manuals