Intended use
The Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories, use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.
Downloading further instructions
A complete user's guide can be downloaded from the
Internet at www.balluff.com/downloads-btl5 or
www.balluff.com/downloads-btl7 or requested via
e-mail from service@balluff.de.
Further information, particularly on the interfaces
and electrical connection, can be found in the
respective user's guide.
Dimensions and function
The transducer contains the waveguide which is protected
by an outer stainless steel tube (rod). A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
BTL5/7-...-CD-... is a high-pressure transducer. Please
note that the magnet used, e.g. BTL-P-1018-3R, must
have the same pressure rating.
Magnet (not included in scope of delivery)
BTL-P-1018-3R (for high-pressure operation)
Weight: Approx. 19 g
Housing: Anodized aluminum
Ø 4.3
120°
Ø 18
Ø 28.5
Ø 39
4
8
Ø 8
english
EU Directive 2004/108/EG (EMC Directive) and EMC law
Generic standards: EN 61000-6-4 (emission), EN 61000-6-2 (noise immunity)
Emission tests: RF emission EN 55016-2-3 Group 1, Class A and B
File no.
E227256
0.5 Ø 31
25
60
Ø 12.7
46
1)
1)
Thread M4x4/6 deep
1) Unusable area
2) Not included in scope of delivery
Thread size:
M22x1.5
30-1 mm
Magnet
Nominal length =
Measuring range
Damping zone
Mounting surface
2)
BTL5/7-...-CD-...