Example
# ATPN=B&T-1,test123456
[ATPN] OK
# ATPS=0,4004
#
[ATPS] OK
[ATPS] con_id=1
# ATPI
con_id:1,server,tcp,address:192.168.20.115,port:4004,so
cket:0
[ATPI] OK
4.8
ATPP-ping command
ATPP=<Remote IP>,[count]
Or
ATPP=<con_id>, [count/loop]
Description
Modify MAC address
Response
Success
[ATPP] OK
Fail
[ATPP] ERROR:<error_no>
Parameter
Remote IP: indicates the IP address or domain name
count: ping the number of times
loop: ping all the time (note that this operation will not return, there is a ping
message printed in the log port)
Error
Code
1: The Command format error
2: The con_id is invalid.
Example
# ATPN=B&T-1,test123456
[ATPN] OK
# ATPP=www.baidu.com,1
[ATPP] OK
4.9
ATPU-set passthrough mode
ATPU=<enable>
Description
Set the passthrough mode
Response
Success
[ATPU] OK
Fail
[ATPU] ERROR:<error_no>
Parameter
enable: 1(Enable the passthrough mode and cannot be disabled after it is
enabled)
Error
Code
1: Parameter error
2: No connection is available.