EasyManuals Logo

Banner PICO-GUARD SFCDT-4A1 User Manual

Banner PICO-GUARD SFCDT-4A1
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
4 P/N 69761 rev. B
Banner Engineering Corp. Minneapolis, U.S.A.
www.bannerengineering.com Tel: 763.544.3164
PICO-GUARD Controller
Instruction Manual
Transparency is used on this drawing...
(scaled down to 1/2)
C
onfiguration
C
onfiguration
C
onfiguration
A
ut o
/M
a
nA
ut o
/M
a
nA
ut o
/M
a
n
TTT
ri
p
/L
atc
hri
p
/L
atc
hri
p
/L
atc
h
/
2
E D
M1
/
2
E D
M1
/
2
E D
M
1
Off/O
n1
Off/O
n1
Off/O
n
2
Off/O
n2
Off/O
n2
Off/O
n
3
Off/O
n3
Off/O
n3
Off/O
n
4 Off/O
n
4 Off/O
n
4 Off/O
n
AAA
BBB
C
hanne
lC
hanne
lC
hanne
l
Reset
a-b c-d a-b c-d
a-b a-b
1 2
USSI 1 USSI 2 EDM 1 O
SSDEDM 2
ChannelSystem
1 2 3 4Status Reset
Banner Engineering Corp., USA
www.bannerengineering.com
S
FCDT-4A1 PICO-GUARD Controlle
rS
FCDT-4A1 PICO-GUARD Controlle
r
763-544-3164
Correct use of this control device is an essential part of
proper machine control. Always follow the instructions in the
manual. Failure to follow all in structions or warnings could
lead to serious bodily injury or death.
WARNING
24Vdc, 0.5A
Channel 13ms; USSI 7m
s
IEC IP20, NEMA
1
0 - 50
C
24Vdc, 0.5A
24Vdc, 0.25A
Cat. 4 (ISO 13849 / EN954),
Type 4 (IEC 61496-1, -2)
Rated Supply:
Response Time
:
Enclosure Rating:
Te
mperature Rating:
OSSD Rating:
Device Type:
Aux, Weak, Fault Rating:
1 2 3 4 5 7 8 9 10 12 13 14 15 17 18
1
2 3 4 5 7 8 9 10 12 13 14 15 17 1
8
OSSDEDM 1USSI 2USSI 1
1 2a b c d
Reset
EDM 2
a b a ba b c d
313029272625232120 28
Tx-0 Vdc Tx+Reset
24
Vdc
0
Vdc Aux Weak Fault
Remote Interface
V+
36
353433
Ch3Ch2 Ch4
Ch1
System
272625232120
31302928
36353433
R1
R2
R3
R4
E1
E2
E3
E4
35 mm
66 mm
(2.6")
132 mm
(5.2")
93.8 mm
(3.69")
112.4 mm
(4.43")
7 mm
(0.27")
122.6 mm
(4.78")
85.5 mm
(3.37")
2.3 Accessories
* NOTE: If used, two contactors per controller are required.
See Figures 3.7 and 3.10.
2.5 Literature
2.6 Dimensions
2.4 Replacement Parts
Components and Specifications
SFA-FA
In-line signal attenuator
SFA-FS
Fiber splice
SFA-RD
Remote display
PFC-2-25
Bag of 25 PFC-2 plastic optical fiber cutters
FS64P100
Black PVC sheathing, 100'
MGA-KSO-1
SPST keyed reset switch
IM-T-9A
Interface module (3 N/O redundant-output
contacts)
IM-T-11A
Interface module (2 N/O redundant-output
contacts plus 1 N/C auxiliary contact)
11-BG00-31-D-024 10 amp positive-guided contactor
3 N/O, 1 N/C*
11-BF16C01-024 16 amp positive-guided contactor
3 N/O, 1 N/C*
SFA-CTB1
PICO-GUARD Controller 4-position terminal block
SFA-CTB2
Fiber splice
SFA-CTB3
Remote display
SFA-CTB4
Bag of 25 PFC-2 plastic optical fiber cutters
SFA-CMH
Black PVC sheathing, 100'
SFA-IAG
SPST keyed reset switch
69761
PICO-GUARD Controller Manual
69765
Daily Checkout Card
69766
Semi-Annual Checkout Card
69763
PICO-GUARD Application and Design Guide
109963
PICO-GUARD CD with Software Programs

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Banner PICO-GUARD SFCDT-4A1 and is the answer not in the manual?

Banner PICO-GUARD SFCDT-4A1 Specifications

General IconGeneral
BrandBanner
ModelPICO-GUARD SFCDT-4A1
CategoryController
LanguageEnglish

Related product manuals