2. Lock or unlock the sensor buttons.
Action Result
Single-pulse the remote input to unlock the sensor.
T
displays and the sensor returns to
Run mode.
Double-pulse the remote input to lock the sensor.
T T
T
displays and the sensor returns to
Run mode.
Triple-pulse the remote input to apply the operator
lock to the sensor
T T
T
T
T
displays and the sensor returns to
Run mode
3.5 TEACH Procedures
Use the following procedures to teach the sensor.
To cancel a TEACH procedure, press TEACH for longer than 2 seconds, or hold the remote input low for longer than 2
seconds.
momentarily displays when a TEACH procedure is canceled.
3.5.1 Two-Point TEACH
Two-point TEACH sets the distance values associated with 0 V and 10 V (4 mA and 20 mA) based on taught target
distances.
Figure 21. Two-Point TEACH
10 V
0 V
2
Press and Hold
> 2s
3
Press again
4
Teach 0 V
Teach 10 V
1
5
Press again
Note: The sensor must be set to = to use the following instructions.
Note: To program the sensor using remote input, remote input must be enabled ( = ).
1. Present the target.
Method Action Result
Push Button
Present the first target. The sensor-to-target distance must be within
the sensor's range.
The target's measurement value
displays.
Remote Input
2. Start the TEACH mode.
Method Action Result
Push Button Press and hold TEACH for longer than 2 seconds.
and flash alternately
on the display. The 2-Pt indicator
flashes.
Remote Input
Single-pulse the remote input.
T