5.8 Settings main menu
PIN code: Protect the projector from usage with a PIN. If enabled the projector will ask for
the PIN at every start up.
network: Set IP address, Subnet mask and default gateway TCP/UDP port number.
DHCP is supported and is enabled by default, but can be disabled.
factory reset: Restore all settings to the factory defined values.
service: End user protected settings. Access PIN code required.
standby ECO mode Power saving mode sending the projector into a deep sleep setting when in
standby. Wake up can be performed either by pressing the power button on the
projector/remote control or remotely via the RS232 connector using the ASCII
protocol / wake on LAN via the ethernet. If DPMS is enabled and a source signal
becomes active again the projector will return to normal operation.
When in standby ECO mode, the baudrate of the RS232 communication is fixed
at 19200.
DPMS: Enable or disable DPMS power saving. This feature is used to automatically
power down the projector if no source is detected for a given period of time
(defined by DPMS timeout). If the projector is powered down in DPMS power
save, it will automatically power back on if a valid source is acquired.
DPMS timeout: Set the period of time before the projector automatically enters DPMS mode.
DPMS must be enabled for this menu item to activate.
LED indicators mute: Disable all LED indicators on top of the projector. A critical error (status LED
flashing RED) will still be enabled.
menu timeout: The time interval before the OSD is automatically disabled. Option of “never” is
available if the OSD is never to time out.
background: Gives a choice between white, gray or black background color.
splash: Possibility to choose between logo or black for the startup splash screen.
baudrate: Presents alternative bauderate settings:
4800, 9600, 19200, 38400, 57600, 115200