35R5905753 /17 DPxK-19B/23B/P
Image 39 Terminal strip accessible
The terminal strip and connection plate is accessible.
3.4 Connecting the DPxK-19B/23B/P with the
power net
WARNING: The total electrical installation should be protected by an appropriate rated and readily
accessible disconnect switch, circuit breakers and ground fault current interrupters. The installation
shall be done according to the local electrical installation codes.
WARNING: Make sure that the voltage range of projector matches with the voltage of the local
power net.
CAUTION: The cross-sectional area of the conductors in the Power Supply Cord shall be not less
than 4 mm
2
or AWG 10
Required tools
Flat torque screw driver
Adjustable wrench
Required parts
Certified power supply cord 4.0 mm², 10AWG, min. 300V, diameter between 11 mm and 21 mm
Circuit breaker maximum 40A
How to connect
1. Remove the back cover.
2. Remove the power input cover.
3. Loosen the cable gland fixation ring (1).
Note: The cable gland (1) is specified for cables with a diameter between 11mm and 21mm.