R5910551 /00 Eonis 31
Immunity to RF wireless communications equipment
Test
frequency
(MHz)
Band (MHz)
Service Modulation
Maximum
power (W)
Distance
(m)
Immunity
test level (V/
m)
385 380 390 TETRA 400 Pulse
modulation
18 Hz
1.8 0.3 27
450 430 470 GMRS 460,
FRS 460
FM ± 5 kHz
deviation
1 kHz sine
2 0.3 28
710 704 787 LTE Band
13, 17
Pulse
modulation
217 Hz
0.2 0.3 9
745
780
810 800 960 GSM 800/
900, TETRA
800, iDEN
820, CDMA
850, LTE
Band 5
Pulse
modulation
18 Hz
2 0.3 28
870
930
1720 1700 1990 GSM 1800,
CDMA 1900,
GSM 1900,
DECT, LTE
Band 1/3/4/
25, UMTS
Pulse
modulation
217 Hz
2 0.3 28
1845
1970
2450 2400 2570 Bluetooth,
WLAN,
802.11 b/g/n,
RFID 2450,
LTE Band 7
Pulse
modulation
217 Hz
2 0.3 28
5240 5100 5800 W LAN
802.11 a/n
Pulse
modulation
217 Hz
0.2 0.3 9
5500
5785
5.6 Explanation of symbols
Symbols on the device
On the device or power supply, you may find the following symbols (nonrestrictive list):
Indicates the device meets the requirements of the applicable EC directives.
Indicates compliance with Part 15 of the FCC rules (Class A or Class B)
E346057
Indicates the device is approved according to the UL regulations for Canada and US
Important information