240 Harvester Feller/
Buncher
1 VIN Open VIN out of range, will create a VIN error =>
VIN=Predefined error value (a)
2 VIN Short-circuited to +BAT VIN out of range, will create a VIN error =>
VIN=Predefined error value (a)
3 VIN Short-circuited to -BAT VIN out of range, will create a VIN error =>
VIN=Predefined error value (a)
IQAN XA2IQAN XA2
IQAN XA2IQAN XA2
IQAN XA2
FAILURE MODE
(a). Measure is controlled by CAN master and application as a result from the CAN error message.(a). Measure is controlled by CAN master and application as a result from the CAN error message.
(a). Measure is controlled by CAN master and application as a result from the CAN error message.(a). Measure is controlled by CAN master and application as a result from the CAN error message.
(a). Measure is controlled by CAN master and application as a result from the CAN error message.
Turning outputs off is controlled by CAN master unit and therefore delayed maximum 2 bus cycles.Turning outputs off is controlled by CAN master unit and therefore delayed maximum 2 bus cycles.
Turning outputs off is controlled by CAN master unit and therefore delayed maximum 2 bus cycles.Turning outputs off is controlled by CAN master unit and therefore delayed maximum 2 bus cycles.
Turning outputs off is controlled by CAN master unit and therefore delayed maximum 2 bus cycles.
Failure modeFailure mode
Failure modeFailure mode
Failure mode
EffectEffect
EffectEffect
Effect
Failure modes for VINFailure modes for VIN
Failure modes for VINFailure modes for VIN
Failure modes for VIN
1 DIN Open No effect on module, not detected
2 DIN Short-circuited to +BAT No effect on module, not detected
3 DIN Short-circuited to -BAT No effect on module, not detected
Failure modeFailure mode
Failure modeFailure mode
Failure mode
EffectEffect
EffectEffect
Effect
Failure modes for DINFailure modes for DIN
Failure modes for DINFailure modes for DIN
Failure modes for DIN
1 FIN Open No effect on module, not detected
2 FIN Short-circuit to +BAT No effect on module, not detected
3 FIN Short-circuit to -BAT No effect on module, not detected
Failure modeFailure mode
Failure modeFailure mode
Failure mode
EffectEffect
EffectEffect
Effect
Failure modes for FINFailure modes for FIN
Failure modes for FINFailure modes for FIN
Failure modes for FIN
1 DFIN Open No effect on module, not detected
2 DFIN Short-circuit to +BAT No effect on module, not detected
3 DFIN Short-circuit to -BAT No effect on module, not detected
Failure modeFailure mode
Failure modeFailure mode
Failure mode
EffectEffect
EffectEffect
Effect
Failure modes for DFINFailure modes for DFIN
Failure modes for DFINFailure modes for DFIN
Failure modes for DFIN