6
MODEL
NO
HP VOLT PH Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
1.2 SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N ▲
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
MAIN - - START
3SHVC Pump
3SHVC3074 3.0
208
1 60 1750
D 14.9 18.5 59.1 125496 12/4 - 18/4 .86 ± .02 0.88 - 2.14
230 F 14.1 16.5 66.3 125496 12/4 - 18/4 .86 ± .02 0.88 - 2.14
3SHVC30N4 3.0
208
3 60 1750 K
9.7 11.4 58.2 125496 12/4 - 18/4 .86 ± .02 1.08
230 9.2 10.6 65.8 125496 12/4 - 18/4 .86 ± .02 1.08
460 4.6 5.3 32.9 125497 12/4 - 18/4 .86 ± .02 4.32
3SHVC3054 3.0 575 3 60 1750 N 4.5 4.9 37 125497 12/4 - 18/4 .86 ± .02 4.32
3SHVC5074 5.0
208
1 60 1750
D 27.2 35.6 99.9 125498 8/4 - 18/4 1.12 ± .02 0.50 - - 2.66
230 F 25.4 30.2 112.4 125496 12/4 - 18/4 .86 ± .02 0.50 - - 2.66
3SHVC50N4 5.0
208
3 60 1750 J
15.8 18.7 82.4 125496 12/4 - 18/4 .86 ± .02 0.72
230 15 17.2 92.4 125496 12/4 - 18/4 .86 ± .02 0.72
460 7.5 8.6 46.2 125497 12/4 - 18/4 .86 ± .02 2.88
3SHVC5054 5.0 575 3 60 1750 J 6 6.9 37 125497 12/4 - 18/4 .86 ± .02 4.32
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5% Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Sufx: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
▲ Cord sold separately.
Single Phase pumps require start components to be included in panel. Provided with pump.
CHART ‘A’