8
MODEL
NO
HP VOLT PH Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
1.2 SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N ▲
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
MAIN - - START
3SHVRA Pump
3SHVRA2074 2.0
208
1
60 1750 G 10.4 12.1 59.1 125496 12/4 - 18/4 .86 ± .02 0.88 -- 2.14
230 60 1750 J 10.7 11.9 66.3 125496 12/4 - 18/4 .86 ± .02 0.88 -- 2.14
3SHVRA20N4 2.0
208
3
60 1750
P
7.4 8.3 58.2 125496 12/4 - 18/4 .86 ± .02 1.08
230 60 1750 7.4 8.0 65.8 125496 12/4 - 18/4 .86 ± .02 1.08
460 60 1750 3.7 4 32.9 125497 12/4 - 18/4 .86 ± .02 4.32
3SHVRA2054 2.0 575 3 60 1750 T 3.9 4.2 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
3SHVRA3074 3.0
208
1
60 1750 D 14.9 18.5 37.0 125496 12/4 - 18/4 .86 ± .02 0.88 -- 2.14
230 60 1750 F 14.1 16.5 66.3 125496 12/4 - 18/4 .86 ± .02 0.88 -- 2.14
3SHVRA30N4 3.0
208
3
60 1750
K
9.7 11.4 58.2 125496 12/4 - 18/4 .86 ± .02 1.08
230 60 1750 9.2 10.6 65.8 125496 12/4 - 18/4 .86 ± .02 1.08
460 60 1750 4.6 5.3 32.9 125497 12/4 - 18/4 .86 ± .02 4.32
3SHVRA3054 3.0 575 3 60 1750 N 4.5 4.9 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
3SHVRA5074 5.0
208
1
60 1750 D 27.2 35.6 99.9 125498 8/4 - 18/4 1.12 ± .02 0.50 -- 2.66
230 60 1750 F 25.4 30.2 112.4 125498 12/4 - 18/4 1.12 ± .02 0.50 -- 2.66
3SHVRA50N4 5.0
208
3
60 1750
J
15.8 18.7 82.4 125496 12/4 - 18/4 .86 ± .02 0.72
230 60 1750 15 17.2 92.4 125496 12/4 - 18/4 .86 ± .02 0.72
460 60 1750 7.5 8.6 46.2 125497 12/4 - 18/4 .86 ± .02 2.88
3SHVRA5054 5.0 575 3 60 1750 J 6 6.9 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
3SHVRA75N4 7.5
208
3
60 1750
H
23.8 28.5 105.9 125496 12/4 - 18/4 .86 ± .02 0.43
230 60 1750 23.7 27.2 123.6 125496 12/4 - 18/4 .86 ± .02 0.43
460 60 1750 11.9 13.6 61.8 125497 12/4 - 18/4 .86 ± .02 1.72
3SHVRA7554 7.5 575 3 60 1750 H 9.5 10.9 49.4 125497 12/4 - 18/4 .86 ± .02 2.69
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5% Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Sufx: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
▲ Cord sold separately.
Single Phase pumps require start components to be included in panel. Provided with pump.
CHART ‘C’