9 Troubleshooting
System faults are distinguished into two general categories:
Faults that are automatically detected by the controller and therefore can be
displayed using error messages
Faults that the controller cannot detect
9.1 Faults with error messages
Error indication in
the display
Possible causes Measures
Flashing
Sensor cable is inter-
rupted
Check cable
Defective sensor
Check sensor resistance
and replace sensor if
necessary
Flashing
Short-circuit in the sensor
cable
Check cable
Defective sensor
Check sensor resistance
and replace sensor if nec-
essary
Circulation error:
No ow
+
Flashing
Additional display
for energy yield
measurement:
Error in the pump con-
nection
Check wiring
Defective pump
Replace pump
Air in the system
Deaerate the system
Defective ow meter
Check whether the ow
meter impeller moves
freely when the system is
running (if visible)
Defective connection to
the ow meter
Check cable
Sensor cable is inter-
rupted
Check cable
Defective sensor
Check sensor resistance
and replace sensor if
necessary