DGC-2020ES Revision History
Revision History
Table 16 provides a historical summary of the changes made to the DGC-2020ES hardware. Firmware
changes are listed in Table 17 and software changes are listed in Table 18. The corresponding revisions
made to this instruction manual are summarized in Table 19. Revisions are listed in chronological order.
Table 16. Hardware Revision History
Hardware
Version and Date
Change
A, Mar-13
Initial release
B, Jun-13
Maintenance release
C, Apr-14
Released firmware version 1.01.00
D, May-14
Released firmware version 1.01.01
E, Nov-14
Released firmware version 1.02.00 and BESTCOMSPlus 3.07.00
F, Jul-15
Released firmware version 1.03.00 and BESTCOMSPlus 3.14.00
G, Aug-16
Front panel upgraded with a membrane switch overlay
Table 17. Firmware Revision History
Firmware
Version and Date
Change
1.00.00, Mar-13
Initial release
1.01.00, Jan-14
Changed to make horn always sound for pre-alarm after alarm
silence button is pressed
Extended minimum range of Low Coolant Temp Pre-alarm down to 0
degrees F
Changed to prevent default run statistics after firmware upload
Modified Diesel Particulate Filter Soot Level and Regeneration
Required Status Information to use the Diesel Particulate Filter
Status parameter (SPN 3701)
Added a one-line diagram to the Front-Panel Overview screen
Improved the Event Log
Increased number of events to 50
Added Scania Engine ECU support
Added Diesel Exhaust Fluid Level on Overview screen on systems
which have Selective Catalytic Reduction with Diesel Exhaust Fluid
implemented
Added Diesel Exhaust Fluid Tank Level and Percent kW Load to
Configurable Metering
Modified Cummins Proprietary J1939 communications to support
Cummins QSX-15 model and run at RPM selected under Speed
Setup
Modified Volvo Proprietary J1939 communications to support RPM
selection
Added ATS Programmable Function Setting to HMI
Removed Contact Input Recognition Parameter as a setting for the
ATS Programmable Function
Removed Contact Input Recognition Parameter as a setting for the
Low Coolant Level, Batt Charger Fail, and Fuel Leak Detect
Programmable Functions
Removed Contact Input Recognition Parameter as a setting for the
Low Fuel Level Programmable Function
Added logic point for DPF Lamp Status from Diesel Particulate Filter
Control 1 PGN

Table of Contents

Other manuals for Basler DGC-2020ES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler DGC-2020ES and is the answer not in the manual?

Basler DGC-2020ES Specifications

General IconGeneral
BrandBasler
ModelDGC-2020ES
CategoryController
LanguageEnglish

Related product manuals