MEC, STAR
Litografi a Reverberi - Pr
Rev. 09 del 01.07.2021
Rotary vanes
vacuum pump
Centrifugal pump
Rotary postive displacement
lobes pump
Rotary postive displacement
lobes pump
Rotary lobes
vacuum pump
MANUALE ISTRUZIONI
PER L’USO E LA MANUTENZIONE
INSTRUCTION MANUAL FOR
USE AND MAINTENANCE
NOTICE D’EMPLOI
ET D’ENTRETIEN
GEBRAUCHS-UND
WARTUNGSANLEITUNGEN
MANUAL DE INSTRUCCIONES
DE USO Y MANTENIMIENTO
MANUAL DE INSTRUÇÕES PARA
USO E MANUTENÇÃO
PODRĘCZNIK INSTRUKCJI
OBSŁUGI I KONSERWACJI
IT
GB
FR
DE
ES
PT
PL
NL
ZH
Via Ferrari N. 2
43058 Sorbolo Mezzani (PR) - Italy
Ph. +39 0521 663203
Fax +39 0521 663206
www.bapag.it
info@bapag.it
MEC, STAR

Table of Contents

Questions and Answers

  • S
    Shane HernandezAug 12, 2025
    Why is my battioni Pagani MEC 1000 Water Pump overheating?
    • A
      Alyssa KelleyAug 12, 2025
      If your battioni Pagani Water Pump is overheating due to excessive pressure, reduce the pressure. If the overheating is caused by an excessive rate of revs, reduce the rate of revs. Should the issue stem from excessive operating time, reduce the operating time. If the blades are too long, trim them to the correct size. Finally, check the oil level in the tank, the oil pump operation, and the setting of the oil tap in case of lack of lubrication.
  • S
    Stephanie StricklandAug 16, 2025
    Why is there little vacuum or pressure in my battioni Pagani MEC 1000 Water Pump?
    • D
      danielleloweryAug 16, 2025
      If your battioni Pagani Water Pump has little vacuum or pressure, it could be due to several reasons. If the cylinder is undulated, smooth or replace the body. If the reversing gear is badly positioned, remove it and position it correctly. If the flange assembly is too tight, add a gasket to the back flange. For Mec 9000-11000-13500-16500 models, if there's displacement of the sliding flange, reinsert the pins supplied between the body and flange for alignment.
  • J
    Justin GonzalezAug 19, 2025
    What to do if P.T.O. does not rotate on battioni Pagani MEC 1000 Water Pump?
    • T
      Theresa JonesAug 19, 2025
      If the P.T.O. of your battioni Pagani Water Pump does not rotate, first check for broken blades and replace them, also check if the rotor pin is bent. Second, check for any foreign body in the rotary blades vacuum pump and remove it. Third, ensure that the handle and reversing gear are correctly positioned. If the rotary blades vacuum pump rotates in the wrong direction, reverse the direction of rotation. Finally, if all blades are jammed or protrude anomalously from the rotor slots, disassemble the rotary blades vacuum pump, then clean and wash the blades, rotor, and body.
  • D
    Daniel RodriguezAug 23, 2025
    Why is my battioni Pagani MEC 1000 Water Pump beating against the external surface?
    • J
      Jim ChristianAug 25, 2025
      If your battioni Pagani Water Pump is beating against an external surface, it might be due to a rate of revs that is too low; in this case, increase the rate of revs. Alternatively, it could be caused by excessive/short and/or not suitable lubrication oil; in this case, clean the rotary blades pump and replace the oil.
  • B
    Brian ThomasAug 27, 2025
    How to fix no circulation of lubricating oil in battioni Pagani Water Pump?
    • M
      Matthew MillerAug 27, 2025
      If there is no circulation of lubricating oil in your battioni Pagani Water Pump (for versions with automatic lubrication), it could be due to air intake at pipe fittings. In this case, replace the pipe fittings. Also, ensure that the lubrication tube is correctly inserted in the pipe fittings. Finally, if there is air in the oil pump chamber, fill the pump chamber with oil.
  • F
    Francis LesterAug 31, 2025
    Why does smoke come out of the discharge elbow of my battioni Pagani Water Pump?
    • J
      James MackAug 31, 2025
      If smoke comes out of the discharge elbow of your battioni Pagani Water Pump, it is likely due to excessive lubrication. Adjust the lubrication to resolve this issue.
  • X
    xcameronSep 3, 2025
    What to do if sewage comes out of discharge elbow of battioni Pagani MEC 1000?
    • I
      Isabella SmithSep 3, 2025
      If sewage is coming out of the discharge elbow of your battioni Pagani Water Pump, the valves may be malfunctioning. Check the valves to resolve this issue.
  • L
    lewiselizabethSep 8, 2025
    How to fix jammed blades in rotor of battioni Pagani MEC 1000?
    • S
      soneillSep 8, 2025
      If some blades are jammed in the rotor of your battioni Pagani Water Pump, disassemble the rotary blades vacuum pump, then clean and wash the rotor, blades, and body.

Summary

Introduction to Battioni Pagani Pumps

Battioni Pagani Pump Guarantee Terms

Obligatory Safety Signs and Conditions of Use

Obligatory Safety Signs Display

Mandatory safety signs for workplace and pump vicinity.

Conditions and Limits of Use

Specifies operating conditions and limitations to ensure safe use.

Set-up of the Lubrication System

Normal Lubrication System

Explanation of the standard lubrication method for the pump.

Forced Lubrication System

Details on the forced lubrication system and its operation.

Automatic Lubrication System

Description of the automatic lubrication system for enhanced convenience.

Recommended Oil Types and Usage

Information on recommended and prohibited oil types.

Oil Level Check Procedures

Instructions on how to check and maintain the oil level.

Overpressure and Vacuum Adjustment Valves

Pump Testing and Running-In Procedures

Pump Testing Procedures

Steps for testing the pump before operation.

Running-In Period Guidance

Guidance on the initial run-in period for the pump.

Start, Operation, and Stop Procedures

Pump Start-Up Procedure

Instructions on how to start the vacuum pump.

Pump Operation Guidelines

How to operate the pump safely and effectively.

Pump Stop Procedure

Steps to safely stop the vacuum pump.

Controls and Indicators Overview

Explanation of the pump's controls and indicators.

Temperature Indicator (Thermo Tape)

Information on the thermo tape for monitoring pump temperature.

Protective Devices

Details on the safety protective devices integrated into the pump.

Individual Means of Protection

Recommended personal protective equipment for safe operation.

Troubleshooting Common Issues

Maintenance, Inspections, and Checks

Cleaning Procedures

Instructions for cleaning the pump and its components.

Checking of Valves

How to regularly check the functionality of the valves.

Inspection and Replacement of Blades

Procedures for inspecting and replacing pump blades.

Technical Assistance and Regular Servicing

Technical Assistance

Information on how to obtain technical support and spare parts.

Regular Servicing Schedule

Recommended maintenance schedule and procedures for regular servicing.

Putting Out of Service and Demolition

battioni Pagani MEC 1000 Specifications

General IconGeneral
Brandbattioni Pagani
ModelMEC 1000
CategoryWater Pump
LanguageEnglish

Related product manuals