Connection
cross section
Connection
method
Torque Load capacity
2)
of the connector
X101
1)
Brake resistor
BM503X-
XX0X
Max. 6 mm² Plug connector,
sp
ring-clamp
- Max. 41A
BM504X Max. 16 mm² Plug connector,
th
readed connection
Min. 1.7 Nm Max. 76 A
X101
1)
Quick-discharge
resistor
BM517X
BM519X
Max. 2.5 mm² Plug connector,
th
readed connection
Min. 0.5 Nm
Max. 0.6 Nm
Max. 16A
BM519X Max. 16 mm² Plug connector,
th
readed connection
Min. 1.7 Nm Max. 76 A
Installation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
167
of 328
7
1)
Not short-circuit resistant - observe maximum load! Refer to „External brake resistor“ in Chapter ZBrake re-
sistors– as fro
m page 265, it is prohibited to connect an additional capacitance
2)
Refer to „External brake resistor continuous power“ in Chapter ZElectrical data– as from page 58.
Connection
cross section
at rated power/
connection
Connection
c
ross section
terminal
Connec-
tion
method
Torque Load
capacity
Motor
1U2, 1V2, 1W2
BM5323
BM5325
Min.
0.
75 mm²
a)
Max. 2.5 mm²
a)
Plug
connector,
threaded
connector
Min. 0.4 Nm
Max. 0.5 Nm
Limited by
th
e device.
Refer to also
ZElec
trical
data– as
from page 58
BM5326
BM5331
Min. 2.5 mm²
a)
Min. 2.5 mm²
a)
Max. 6 mm²
a)
Plug
connector,
spring-
clamp con-
nection
-
BM5327
BM5332
Min. 4 mm²
a)
BM5328
BM5333
Min. 6 mm²
a)
BM5334 Min. 10 mm²
a)
Min. 4 mm²
b)
Min. 10 mm²
c)
Max. 25 mm²
a)
Screw
terminal
Min. 4.0 Nm
Max. 4.5 Nm
BM5335 Min. 16 mm²
a)
BM537X 2 x 16 mm²
d)
Cable lug
for M8
Min. 10 Nm
Max. 13 Nm
50 mm²
d)
a)
with or without wire end ferrule
b)
only with wire end ferrule
c)
without wire end ferrule
d)
The cable lug may be 20 mm wide at most. The maximum cable diameter is dependent on the cable lug. Also
see ZC
able device - motor– as from page 242.