EasyManua.ls Logo

Baumuller BM5300 Series - Page 168

Baumuller BM5300 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connection cross section Connection
method
Torque Load
capacity
Motor PE BM5323
BM5325
BM5331
BM5332
BM5333
refer to motor cable Cable lug
fo
r M4
Min. 1.4 Nm
Max. 1.8 Nm
see
ZElectrical
dataas
from page
58
BM5326
BM5327
BM5328
BM5334
BM5335
refer to motor cable Cable lug
fo
r M5
Min. 2.2 Nm
Max. 3.0 Nm
BM537X refer to motor cable Cable lug
fo
r M8
Min. 10 Nm
Max. 13 Nm
Connection
cro
ss section
Connection
method
Load capacity
X200 (SEL
V/PELV)
24 V voltage supply
Max. 1.5 mm²
(2 wire 2 pin)
Plug connector,
spring-clamp con-
nection
Max. 2.0 A
plug connector, max. 16 A
Connection
cro
ss section
Connection
method
Load capacity
X1 (SEL
V/PELV)
Control inputs
BM503X-
XX0X
Max. 1.5 mm² Plug connector,
spring-clamp con-
nection
Max. 8.0 A
X2 (SEL
V/PELV)
DIO
Max. 1.0 mm² Plug connector,
spring-clamp
connection
Max. 8.0 A
X206 (SEL
V/PELV)
Supply for motor
t
emperature and
brake
all other
devices
Max. 1.5 mm² Plug connector,
sp
ring-clamp
connection
Max. 4 A
BM537X Max. 2,5 mm² Max. 16 A
Electrical connections
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
168
of 328
7.14

Table of Contents

Related product manuals