Usage for the intended purpose
Instruction handbook BUM 60 / BUS 60
Document No.: 5.01032.05 Baumüller Nürnberg GmbH
12
of 82
2.3
2.3 Usage for the intended purpose
The device is conceived and constructed exclusively for usage compliant with its intended pur-
pose described in these instruction handbook.
The devices of the model series Mono Power Unit / Power Module BUM 60 / BUS 60 are either
mains rectifier or active mains rectifier in combination with axis units with servo controller. De
-
vices are also available in graduated design size and performance classes.
The device Mono Power Unit / Power Module BUM 60 / BUS 60 is used exclusively as a con-
verter for controlling a motor.
A device is considered as being used compliant with its intended purpose if all notes and infor-
mation of these instruction handbook are adhered to.
WARNING!
Danger arising from usage for an unintended purpose!
Any usage that goes beyond the intended purpose and/or any non-compliant use of
the device can lead to dangerous situations.
Therefore:
m Only use the device compliant with its intended purpose.
m Observe all specifications of these instruction handbook.
m Ensure that only qualified personnel work with/on this device.
m When configuring, ensure that the device is always operated within its specifica-
tions.
m Mount the device on a wall that can sufficiently bear the load.
m The device must always be operated within a control cabinet.
m Ensure that the power supply complies with the stipulated specifications.
m The device may only be operated in a technically flawless condition.
m Only operate the device in combination with components approved by Baumüller
Nürnberg GmbH.
m The device has been developed in such a manner that it fulfills the requirements
of the category C3 according to IEC
61800-3:2005.
m The device is not intended to be connected to the public power supply system. To
operate the device in primary surroundings of the category C2/C1 (residential,
business and commercial areas, directly on a public low-voltage power supply
without an intermediate transformer), special measures to reduce the transient
emissions (line-internal and radiated) must be provided for and certifiable by the
system builder. Otherwise, EMC interference could occur without such additional
measures.