EasyManua.ls Logo

Baumuller BUM 60 - Electrical Data

Baumuller BUM 60
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTICE!
Normally, non-conductive pollution occurs. Conductive pollution is unacceptable.
Conductive pollution can lead to the destruction of the device. The customer is re
-
sponsible for destructions, which were caused by pollution due to conductive materi-
als or components.
Technical Data
Instruction handbook BUM 60 / BUS 60
Document No.: 5.01032.05
27
of 82
3
3.4 Electrical data
3/6 3/6 - 54 -
x - xx6
6/12 6/12 - 54 -
x - xx6
8/16 12/24
Connection voltages
1)
3 x 400 - 480 V
AC
50 - 60 Hz, ± 10 %
Semiconductor fuses (external)
8)
16 A
Type of protection IP 20
Rated DC Link voltage
2)
540 V
DC
DC Link capacitor 110 µF 330 µF 110 µF 330 µF 220 µF 220 µF
Switch-on:
Ready for operation after
1,5 s
Frequency to switch on power sup-
ply
12)
unlimited
Output voltage
9) 10)
3 x 0 V
AC
... 95 % of input voltage
Output power
3) 10)
2 kVA 2 kVA 4,5 kVA 4,5 kVA 6 kVA 8 kVA
Typical motor power
3)
1,1 kW 1,1 kW 2,25 kW 2,25 kW 3 kW 4,5 kW
Rated output current
4) 5) 10) 11)
3 A
eff
3 A
eff
6 A
eff
6 A
eff
8 A
eff
12 A
eff
Peak output current
4) 5) 6) 10)
6 A
eff
6 A
eff
12 A
eff
12 A
eff
16 A
eff
24 A
eff
Low-voltage supply +24 V
DC
± 10 % (max. 55 W)
Ballast resistor R
B
(only BUM 60)
Peak power of ballast resistor
Continuos output
External ballast resistor
7)
10 kW / 1 s
250 W
min. 60
Max. switch-on time / ratio 1,5 s / 1 : 33
Power loss in rated operation,
without low-voltage supply,
without ballast
60 W 60 W 110 W 110 W 130 W 170 W
*
WARNUNG!
With a single-phase connection, neither of the two lines must have ground potential!

Table of Contents

Related product manuals