Inspection intervals - maintenance notes
Instruction handbook BUM 60 / BUS 60
Document No.: 5.01032.05 Baumüller Nürnberg GmbH
62
of 82
9.3
m Mechanical parts
Check points Methods and criteria Inspection intervals
Daily Semi-
annu
-
ally
Annu-
ally
Are there any abnormal noises or vibrations? Visual and audio check O
Are there any loose screws? Tighten the screws. O
Are there any bent or damaged parts? Visual inspection O
Have there been any color changes due to over-
heating?
Visual inspection O
Are there any dust or dirt deposits? Visual inspection O
m Power supply
Check points Methods and criteria Inspection intervals
Daily Semi-
annu
-
ally
Annu-
ally
Are there any missing or loose screws? Replace the screws or, respectively, tighten them. O
Is there any deformation, cracking, damage or
color change on the device as a result of overheat
-
ing or aging?
Visual inspection O
Are there any dust or dirt deposits? Visual inspection O
m Connections and circuitry of the mains power supply
Check points Methods and criteria Inspection intervals
Daily Semi-
annu
-
ally
Annu-
ally
Does the wiring indicate any color or shape
changes due to overheating?
Visual inspection O
Is the wiring insulation damaged or is it discol-
ored?
Visual inspection O
Is there any damage? Visual inspection O
m Transformer and chokes in the main circuit
Check points Methods and criteria Inspection intervals
Daily Semi-
annu
-
ally
Annu-
ally
Are there any abnormal vibrations or noticeable
odors?
Visual inspection, audio check and odor check O