TAM00721 5
DSD-028 / DSD-036 / DSD2-028 / DSD2-036 04/2013
Three-phase-synchronous motor English
1.2 Designated purpose
The electric motor must only be used for its designated purpose.In this context, the electric motor must
only be used for the applications described in the technical documentation under strict observance of all
the notes in these Commissioning and Maintenance Instructions.
All assembly, commissioning, maintenance, and operating tasks must be carried out by qualified
personnel only.
Within the context of these safety instructions, qualified personnel refers to persons who are trained and
authorized in the specialized area, who are authorized to set up, assemble, commission, and operate
units, systems, and circuits under application of the applicable safety standards (EN 50110-1).
Inappropriate behaviour can result in serious injury and damage to property.
The electric motor is designed to be used for industrial applications and is subject to a number of
standards and directives, including the following:
Standards
EN 60034-1, EN 60034-5, EN 60034-6, EN 60034-7, EN 60034-9, EN 60034-11,
EN 60034-14, EN 60204-1
Low Voltage Directive EC
The electric motors in this series fully comply with the requirements of the Low Voltage Directive EC
(conformity).
Machinery Directive EC
Electric motors are components which are intended to be installed in machines as described in the
Machinery Directive. Commissioning is not permitted until such time as the conformity of the finished
product with this directive has been established (refer to EN 60204-1 "Electrical Equipment of
Machines").
EMC Directive EC
When the electric motor is used as intended, its operation must comply with the safety requirements
laid down in the EMC Directive EC. Proper installation (e. g. physical isolation of signal and power
cables, shielded wiring and cable etc.) is the responsibility of the system installer and system
vendor.With systems which have converters, the EMC notes from the manufacturers of the
converter-, encoder- and brake-manufacturer must be observed.
All national, local, and system-specific regulations must also be observed!
The electric motor is designed for the following ambient conditions:
• Ambient temperature: 0 °C to +40 °C
• Altitude: ≤ 1000 m above sea level
• Relative humidity: 5 % to 85 %
Please take note of any deviating details specified on the nameplate or in the technical
documentation. The conditions at the place of use must correspond to the details on the rating plate.
Use in areas with potentially explosive atmospheres is prohibited unless the unit is
expressly designed for this purpose (refer to additional notes).Furthermore, the area
surrounding the electric motor must be free of inflammable gas mixtures and hazardous
concentrations of dust.
Live and hot motor parts are inflammable and may cause serious injury and damage to
property.
If, in special cases (for utilization in non-industrial applications), more stringent
requirements are in place, e. g., protection against contact with a child's fingers, these
conditions must be met by the customer when installing the system.