12 Decommissioning and disposal
12.1 Decommissioning procedure
To decommission the heat pump temporarily or permanently:
1. Switch off the heat pump.
2. Shut off the electrical power supply to the heat pump: outdoor unit and
indoor module.
3. Shut off the supply to the electrical back-up if an electrical back-up is
present.
4. Drain the central heating system.
12.2 Disposal and recycling
Warning
Removal and disposal of the heat pump must be carried out by a
qualified professional in accordance with prevailing local and
national regulations.
1. Switch off the heat pump.
2. Cut the mains supply to the heat pump.
3. Recover the refrigerant in accordance with prevailing regulations.
Important
Do not allow the refrigerant to escape into the atmosphere.
4. Disconnect the refrigerant connections.
5. Close the water mains.
6. Drain the installation.
7. Dismantle all hydraulic connections.
8. Dismantle the heat pump.
9. Scrap or recycle the heat pump in accordance with prevailing local
and national regulations.
Fig.87
MW-3000179-03
12 Decommissioning and disposal
7762758 - v05 - 19082020 95

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baxi Assure AWHP-IDU 4–8 E and is the answer not in the manual?

Baxi Assure AWHP-IDU 4–8 E Specifications

General IconGeneral
BrandBaxi
ModelAssure AWHP-IDU 4–8 E
CategoryHeat Pump
LanguageEnglish

Related product manuals