Appliance Category | Boiler |
---|---|
Boiler Type | Conventional |
Fuel Type | Gas |
Output | 14.65 kW |
Central Heating Flow Temperature | 82°C |
Warranty | 2 Years |
Fuel | Natural Gas |
Guidelines for flushing and adding inhibitor to prevent corrosion and scale in heating systems.
Specifies minimum dimensions and construction requirements for the appliance's installation opening.
Requirements for flue installation, including vertical height, diameter, and approved terminals.
Specifies required permanent ventilation area sizes and optimal siting for combustion air.
Conformance to BS 6891 for gas installation, pipe sizing, and routing.
Requirements for wiring, earthing, polarity, and mains supply connection.
Procedure for connecting the gas supply pipe to the appliance's gas cock.
Requirements for connecting the appliance to the external heating controls system.
Detailed steps for wiring the appliance's mains supply and controls.
Steps for fitting the boiler hood and securely connecting the flue to the outlet socket.
A comprehensive step-by-step guide for initial startup, testing, and system checks.
Detailed steps for safely removing and replacing the main gas valve.
Procedure for safely replacing the pilot burner and flame supervision assembly.