Questions and Answers

  • K
    Kimberly PerezSep 12, 2025
    What causes a Baxi COMBI 424 Boiler to display 'Flow temperature sensor short-circuited'?
    • E
      Edwin WalterSep 12, 2025
      If your Baxi Boiler displays 'Flow temperature sensor short-circuited', it could be due to: * Sensor not or badly connected: Check the wiring. * Bad connection: Check that the sensors are operating correctly. * Sensor fault: Check that the sensor has been correctly fitted and replace the sensor if necessary.
  • W
    William TaylorSep 10, 2025
    What causes a Baxi COMBI 424 Boiler to display 'Return temperature sensor short-circuit'?
    • W
      William JordanSep 10, 2025
      If your Baxi Boiler displays 'Return temperature sensor short-circuit', it could be due to: * Sensor not or badly connected: Check the wiring. * Bad connection: Check that the sensors are operating correctly. * Sensor fault: Check that the sensor has been correctly fitted and replace the sensor if necessary.
  • N
    Nicholas MitchellSep 9, 2025
    What causes a Baxi COMBI 424 to display 'Return temperature sensor open-circuit'?
    • B
      brandon84Sep 9, 2025
      If your Baxi Boiler displays 'Return temperature sensor open-circuit', it could be due to: * Sensor not or badly connected: Check the wiring. * Bad connection: Check that the sensors are operating correctly. * Sensor fault: Check that the sensor has been correctly fitted and replace the sensor if necessary.
  • S
    samanthaschmittSep 8, 2025
    What should I do if my Baxi COMBI 424 displays a 'False flame signal'?
    • K
      Kenneth HernandezSep 8, 2025
      If your Baxi Boiler displays a false flame signal, it could be due to: * Short-term fluctuation of the mains: Press the RESET button for 5 seconds. * Ionization current present even though there is no flame: Replace the ionization/ignition electrode. * Sensor fault: Set the CO2. * Defective gas/air unit: Check the gas/air unit and replace if necessary.
  • M
    Matthew MataAug 23, 2025
    What to do if my Baxi Boiler is not working?
    • C
      Cynthia GarciaAug 23, 2025
      If your Baxi Boiler isn't working, first check that the boiler is being supplied with power by checking the fuses and switches. Ensure that timers and thermostats are calling for heat. If the water pressure is too low (less than 0.5 bar), re-pressurise the system. Check that the gas isolation cock is fully open to ensure adequate gas pressure. Also, press the Reset button, and correct any error if possible. Finally, inspect the condensate drain for blockages, especially in external runs during freezing temperatures.
  • P
    Patrick SmithSep 6, 2025
    What causes a Baxi COMBI 424 to have a communication error with the NTC flue sensor?
    • C
      Casey WalkerSep 6, 2025
      If your Baxi Boiler shows a communication error with the NTC flue sensor, it might be due to the sensor not being connected properly, so check wiring. Another cause may be bad connection, so check sensors are operating correctly. Also, check that the sensor has been correctly fitted. If necessary, replace the sensor.
  • R
    robertgardnerSep 5, 2025
    What to do if my Baxi COMBI 424's maximum flue gas temperature is reached (> 140 Deg C)?
    • D
      Douglas BruceSep 5, 2025
      If the maximum flue gas temperature is reached in your Baxi Boiler, it could be due to: * No circulation: Vent the air in the heating system. * Sensor fault: Check the water pressure, check the wiring, check the circulation (direction, pump, valves), check the cleanliness of the heat exchanger, check that the sensors are operating correctly and replace the sensor if necessary.
  • G
    gosbornSep 4, 2025
    What to do if my Baxi Boiler has no circulation?
    • E
      Elizabeth PettySep 4, 2025
      If your Baxi Boiler has no circulation, it could be due to: * No circulation: Vent the air in the heating system. * Sensor not or badly connected: Check the water pressure and check the wiring. * Sensor fault: Check the circulation (direction, pump, valves), check the cleanliness of the heat exchanger, check that the sensors are operating correctly and replace the sensor if necessary.
  • E
    Edward HigginsSep 2, 2025
    Why is my Baxi Boiler showing a 'Gas Valve fault'?
    • S
      Sara SchroederSep 2, 2025
      If your Baxi Boiler indicates a gas valve fault, the gas valve may not be detected. Check the wiring. Also, check the resistance across gas valve terminals. If necessary, replace gas valve.
  • M
    Mark JonesSep 1, 2025
    How to fix no circulation of water in my Baxi Boiler?
    • K
      Katelyn MartinezSep 1, 2025
      If there is no circulation of water in your Baxi Boiler, it may be due to: * Non-existent or insufficient circulation: Check circulation. * Sensor error: Check water pressure, check sensors are operating correctly, check that the sensor has been correctly fitted, check the cleanliness of the heat exchanger and check pump.

Summary

Safety

General safety instructions

Provides essential safety guidelines for using the boiler and potential hazards.

Technical specifications

Technical data

Presents detailed technical information including general, heating, DHW, and electrical specifications.

Description of the product

Control panel description

Details the components and functions of the boiler's control panel and display screen.

Operation

Start-up

Guides the user through the initial start-up procedure and basic fault identification checks.

Use of the control panel

Explains how to operate the boiler's controls, including temperature settings and reset functions.

Frost protection

Details the boiler's frost protection features and precautions for preventing frost damage.

Settings

Setting the parameters

Explains how to adjust central heating and domestic hot water temperatures using the control buttons.

Maintenance

Troubleshooting

Error codes

Lists and explains temporary and permanent error codes displayed by the boiler, aiding fault diagnosis.

Fault finding

Provides a table of common problems with their possible causes and solutions for troubleshooting.