Questions and Answers

  • D
    daviskimberlyAug 31, 2025
    What should I do if my Baxi COMBI 424 Boiler shows a communication error between the gas valve and PCB?
    • C
      Christian Evans DDSAug 31, 2025
      If your Baxi Boiler displays a communication error between the gas valve and PCB, it could be due to a fault in the air/gas unit, in this case, replace the air gas unit. Alternatively, there might be a loose connection to the gas valve, so check the gas valve connection from the PCB.
  • N
    Natalie HarveyAug 30, 2025
    What should I do if the CH Flow temperature is increasing too fast in my Baxi COMBI 424?
    • C
      Cody LiuAug 30, 2025
      If the CH Flow temperature is increasing too fast in your Baxi Boiler, it could be due to: * Non-existent or insufficient circulation: Check circulation. * Sensor error: Check water pressure, check sensors are operating correctly, check that the sensor has been correctly fitted and check the cleanliness of the heat exchanger.
  • J
    Jessica BensonAug 29, 2025
    How to resolve a Baxi COMBI 424's incorrect fan speed?
    • M
      Michael WestAug 29, 2025
      If your Baxi Boiler's fan speed is incorrect, it could be due to an external draught over the boiler, so check for adequate draw on the chimney connection. It may also be caused by a defective gas/air unit, so check the gas/air unit and replace it if necessary.
  • J
    James HicksAug 28, 2025
    What causes 5 x flame loss in 24 hours with burner on in Baxi COMBI 424 Boiler?
    • Z
      zwilsonAug 28, 2025
      If your Baxi Boiler experiences 5 flame losses in 24 hours while the burner is on, possible causes include: * No ionization current: Purge the gas supply to remove air. * Sensor fault: Check that the gas valve is fully opened, check the supply pressure, check the operation and setting of the gas valve unit, check that the air inlet and flue gas discharge flues are not blocked and check that there is no recirculation of flue gases.
  • A
    Alexander BanksAug 27, 2025
    What causes no flame during operation in a Baxi Boiler?
    • A
      alan47Aug 27, 2025
      If there is no flame during operation in your Baxi Boiler, it could be due to several reasons: * No ionization current: Purge the gas supply to remove air. * Sensor fault: Check the gas valve is fully opened, check the supply pressure, check the operation and setting of the gas valve unit, check the air inlet and flue gas discharge flues are not blocked, check that there is no recirculation of flue gases.
  • A
    Anthony CalderonAug 26, 2025
    Why are my radiators cold with my Baxi Boiler?
    • K
      Kelly BanksAug 27, 2025
      If your radiators are cold when using your Baxi Boiler, first, check the temperature set point for the heating and increase it using the CH temperature knob or your room thermostat. Make sure the heating mode is activated. Ensure that all radiator valves are open. Also, check that the boiler is receiving power by checking the fuses and switches, and verify the gas isolation cock is open. If the water pressure is too low (below 0.5 bar), re-pressurise the system.
  • A
    Anthony DavisAug 25, 2025
    How to fix no domestic hot water in my Baxi COMBI 424 Boiler?
    • C
      Christopher TaylorAug 26, 2025
      If your Baxi Boiler isn't providing domestic hot water, start by ensuring the boiler is receiving power by checking the fuses and switches. Also, verify that the gas isolation cock is fully open and, if applicable, that your prepayment meter has sufficient credit. It's also possible that the DHW function is switched off, so try activating the DHW mode. Check the water pressure; if it's below 0.5 bar, re-pressurise the system. Finally, make sure the flow is at least 2.5 litres per minute.
  • M
    Michael FloydAug 25, 2025
    What to do if my Baxi COMBI 424 has low system water pressure?
    • B
      Brandy DouglasAug 25, 2025
      If your Baxi Boiler shows low system water pressure, it could be due to a water leak. Check the boiler and the entire system for any signs of leakage. You may also need to repressurize the system.

Summary

Safety

General safety instructions

Provides essential safety guidelines for using the boiler and potential hazards.

Technical specifications

Technical data

Presents detailed technical information including general, heating, DHW, and electrical specifications.

Description of the product

Control panel description

Details the components and functions of the boiler's control panel and display screen.

Operation

Start-up

Guides the user through the initial start-up procedure and basic fault identification checks.

Use of the control panel

Explains how to operate the boiler's controls, including temperature settings and reset functions.

Frost protection

Details the boiler's frost protection features and precautions for preventing frost damage.

Settings

Setting the parameters

Explains how to adjust central heating and domestic hot water temperatures using the control buttons.

Maintenance

Troubleshooting

Error codes

Lists and explains temporary and permanent error codes displayed by the boiler, aiding fault diagnosis.

Fault finding

Provides a table of common problems with their possible causes and solutions for troubleshooting.

Decommissioning

Warranty

Baxi COMBI 424 Specifications

General IconGeneral
ModelCOMBI 424
CategoryBoiler
Output24 kW
Fuel TypeNatural Gas
Flow Rate9.8 L/min
MountingWall Mounted
Boiler TypeCombi