Fault code Inquiry mode
Under the normal operation mode to set temperature on remote controller: 16°C;
then press the-”key 10 times continuously within 8 seconds, the buzzer will long
beep four tones to enter fault code inquiry mode.
If there is no error, the indoor digital display will show “CC”; if there has fault, the indoor
digital display will show error code. Such as the indoor digital display displays“1”, it means
the module protection fault.
ERROR CODE
PROBLEM
1
Module Protection Fault
2
PFC Protection Fault
3
Compressor start failure or running out of step fault
4
Compressor exhaust temperature sensor failure
5
Condenser temperature sensor failure
6
Outdoor ambient temperature sensor failure
7
Communication failure between indoor and outdoor
8
Communication failure between main control board and driver board
9
Outdoor Eeprom fault
10
Outdoor fan motor failure
11
Indoor ambient temperature sensor failure
12
Indoor coil temperature sensor failure
13
Indoor fan motor failure
14
Other fault or protection displayed by tooling
15
Compressor casing temp. sensor failure or refrigerant leak
16
Suction temp. sensor failure
17
Compressor overpower protection
18
Overcurrent protection
19
Compressor exhaust temperature protection
20
Overload protection in cooling mode
21
Outlet high temperature protection in heating mode
22
Anti-freezing protection in cooling mode
23
Compressor casing temperature protection
24
Over voltage or low voltage protection
N.B
Fault code Inquiry mode is available only for wall type multisplit indoor units. It could not be
applied to other IDU kind (duct, cassette, floor/ceiling).