3.2 Technical Data
Tab. 1: Technical Data
Model
Product-ID-No.
Installation types B
23
, B
23P
, C
43
, C
53
, C
63
, C
83
, C
93
Power values
Nominal heat input range Heating kW 80,0-400,0 94,0-470,0 108,0-540,0 122,0-610,0
Nominal heat output range 80/60°C
kW 77,0-392,8 91,0-462,0 105,0-531,4 119,0-601,0
C°03/05
kW 84,8-422,4 99,8-498,2 115,0-574,6 130,4-651,5
Standard utilisation (Hi/Hs)
75/60°C % 106,4/95,4 106,1/95,1 106,2/95,2 106,3/95,3
40/30°C % 109,4/98,4 109,3/98,3 109,2/98,2 109,1/98,1
Gas and exhaust side values
Natural gas consumption LL (G25)
m
3
/h
8,5-42,3 9,9-49,7 11,4-57,1 12,9-64,6
Natural gas consumption E (G20)
m
3
/h
9,8-49,2 11,6-57,8 13,3-66,4 15,0-75,0
pmet sag eulF
06C°
Exhaust gas mass flow
kg/h 138,6-679,7 160,6-793,1 182,5-911,5 206,3-1031,4
Supply pressure
mbar min. 18 - max. 25
CO
2
-content natural gas
*
Partial load range
0,9 - 7,8%
egnar daol lluF
3,9 - 0,9%
53 <hWk/gmnoissime xON
Max. delivery pressure at exhaust gas outlet
05,1rabm
Exhaust gas connection
DN 250
Electrical connection values
01XPIgnitar PI
Electrical connection
230 V~ / 50Hz, max. 8,0 A
noitpmusnoc rew
op .rtcele .xaM
Heating operation (full load, without pump)
W 463 583 790 750
Control (protection)
5.3W
Heating side values
Max. water pressure 6,0 bar / 0,6 MPa
Max. operating temperature (protection)
011C°
Max. flow temp
09C°
ecnatsiser ciluardyH
at T=20°C
mbar 101 115 121 132
at T=10°C
mbar 394 444 469 516
Other values
476636895045gkthgiew relioB
Boiler water content
l738497106
6251m
mgnihty
reve evoba thgieH
htdiW
267mm
htpeD
29122881mm
Sound pressure level
dB(A)
*
in case of fluctuating natural gas composition see section 5.8 CO
2
-content
Technical Data
11
1.430 1.500 1.570 1.650

Table of Contents