4.5 Bringing the boiler in tight
spacesi
When bringing the boiler in tight spaces it can be helpful to remove the front
frame, the fan and the Venturi tube with integrated gas valve. In this manner the
heating boiler is shorter and can then be manouvered around tight curves.
Fig. 9: Folding up the control box
2
1
1. Remove front cladding and front side cladding
2. Fold up control box (1) and secure with a lock (2)
3. Remove all connection plugs on the top of the fan
Fig. 10: Loosen the screwed connections
3
4
4. Loosen the screws on the connection piece to the Venturi tube on the bottom
of the fan (3)
5. Remove connection screws to the mixing adapter (4)
Prior to installation
22