Step 3: Conguring the Regeneration Type
Press the DOWN key to enter the regeneration type settings:
A -- 01 = Delayed Regeneration (DO NOT MODIFY)
A -- 02 = Instant Regeneration
To change it, press the “Menu/Conrmation” key and select the type of regeneration using
the UP and DOWN keys. Conrm the option using the “menu/conrmation” key.
Step 4: Setting the F-00 Backwash Interval
Press the DOWN key. Program 1 will appear on the display, which corresponds to the
“backwash interval”, i.e. the number of regenerations until the valve backwashes. For
counter-current valves it is not necessary to perform a backwash on each regeneration,
so this setting allows you to specify how often a backwash will be made. To adjust it, press
“menu/conrmation” and switch with the UP/DOWN buttons to the desired value. Press
“menu/conrmation” to conrm.
F – 00 It is a backwash every time a regeneration is made. (DO NOT MODIFY)
F – 01 It is a backwash every 2 regenerations.
F – 02 It is a backwash every 3 regenerations. And so on.
Step 5: Setting Up Volume to Be Treated
Conguration for volume of water to be treated M3, GALLONS or LITERS (options A-01,
A-02) where we can see the cubic meters, gallons or liters of water to be treated.
We will mark the volume that can be descaled, according to the table.
Press the “menu/conrmation” key again and the value will start ashing.
You can change this amount using the UP and DOWN buttons. Program the appropriate
amount based on the amount (liters) of resin and the hardness of the water. Finally,
conrm with the “menu/conrmation” key.
MODEL Water Quality
Hardness of the water to be treated (French degrees - ºhF)
20 ºhF 30 ºhF 40 ºhF 50 ºhF 60 ºhF 70 ºhF 80 ºhF 100 ºhF
CERAMIC
PILOT 2.0
Liters of water per cycle (L/cycle)
3.000 2.000 1.500 1.200 1.000 857 - -
CERAMIC
PILOT 2.5
Liters of water per cycle (L/cycle)
6.250 4.166 3.125 2.500 2.083 1.785 1.562 1.250