Error code Description Cause/Remedy
E.343
Pull-in safety CLOSEdevice triggered Pull-in safety CLOSEdevice triggered
E.344
Safety unit OSE FE1 triggered
• Safety unit OSE FE1 triggered
• Only with P.510:5.01 and P. 510:5.02
E.350
Safety edge SE1 has switched before
travel in the CLOSE direction
• Defective safety edge
• Safety edge is activated
E.352
Negative test of input SE1 Error on control unit PCB
E.360
Safety edge SE2 has switched before
CLOSE travel
• Defective safety edge
• Safety edge is activated
E.362
Negative test of input SE2 Error on control unit PCB
E.364
No switching impulse from the safety
edge in the lower limit position – test-
ing failed (DW)
• If necessary, re-adjust the pressure wave switch contact
• If necessary, correct the pre-limit switch for the safety edge
E.374
Safety edge testing pre-limit switch
set too high
• Safety edge testing pre-limit switch set too high (MLS)
• VES position programmed too high (AE)
E.408
Communication fault relating to the
M2 expansion board
• Communication between motherboard and extension board disrupted
• BDC-XXX M2 defective
E.768
Battery voltage low TST PD Battery voltage of the TST PD buffer battery is too low, replace battery
E.801
Negative test from light barrier 1
• Light barrier 1 was tested as being defective
• The device connected to the input is not working
E.802
Negative test from light barrier 2
• Light barrier 2 was tested as being defective
• The device connected to the input is not working
E.803
Negative test from pull-in safety
device OPEN
• Testing was unsuccessful
• The device connected to the input is defective
• The cable between the connected device and the control unit is interrup-
ted
E.804
Negative test from pull-in safety
device OPEN and CLOSE
• Testing was unsuccessful
• The device connected to the input is defective
• The cable between the connected device and the control unit is interrup-
ted
E.805
Negative test from pull-in safety
device CLOSE
• Testing was unsuccessful
• The device connected to the input is defective
• The cable between the connected device and the control unit is interrup-
ted
E.806
Negative test from safety edge SE1
• The safety edge SE1 was tested as being defective
• The device connected to the input is not working
E.807
Negative test from safety input SE2
• The safety input SE2 was tested as being defective
• The device connected to the input is not working
E.808
Negative test from wicket door SE2
• The wicket door SE2 was tested as being defective
• The device connected to the input is not working