Error code Description Cause/Remedy
E.343
Pull-in safety CLOSEdevice triggered Pull-in safety CLOSEdevice triggered
E.344
Safety unit OSE FE1 triggered
Safety unit OSE FE1 triggered
Only with P.510:5.01 and P. 510:5.02
E.350
Safety edge SE1 has switched before
travel in the CLOSE direction
Defective safety edge
Safety edge is activated
E.352
Negative test of input SE1 Error on control unit PCB
E.360
Safety edge SE2 has switched before
CLOSE travel
Defective safety edge
Safety edge is activated
E.362
Negative test of input SE2 Error on control unit PCB
E.364
No switching impulse from the safety
edge in the lower limit position – test-
ing failed (DW)
If necessary, re-adjust the pressure wave switch contact
If necessary, correct the pre-limit switch for the safety edge
E.374
Safety edge testing pre-limit switch
set too high
Safety edge testing pre-limit switch set too high (MLS)
VES position programmed too high (AE)
E.408
Communication fault relating to the
M2 expansion board
Communication between motherboard and extension board disrupted
BDC-XXX M2 defective
E.768
Battery voltage low TST PD Battery voltage of the TST PD buffer battery is too low, replace battery
E.801
Negative test from light barrier 1
Light barrier 1 was tested as being defective
The device connected to the input is not working
E.802
Negative test from light barrier 2
Light barrier 2 was tested as being defective
The device connected to the input is not working
E.803
Negative test from pull-in safety
device OPEN
Testing was unsuccessful
The device connected to the input is defective
The cable between the connected device and the control unit is interrup-
ted
E.804
Negative test from pull-in safety
device OPEN and CLOSE
Testing was unsuccessful
The device connected to the input is defective
The cable between the connected device and the control unit is interrup-
ted
E.805
Negative test from pull-in safety
device CLOSE
Testing was unsuccessful
The device connected to the input is defective
The cable between the connected device and the control unit is interrup-
ted
E.806
Negative test from safety edge SE1
The safety edge SE1 was tested as being defective
The device connected to the input is not working
E.807
Negative test from safety input SE2
The safety input SE2 was tested as being defective
The device connected to the input is not working
E.808
Negative test from wicket door SE2
The wicket door SE2 was tested as being defective
The device connected to the input is not working
51

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Becker BDC-i440 Series and is the answer not in the manual?

Becker BDC-i440 Series Specifications

General IconGeneral
BrandBecker
ModelBDC-i440 Series
CategoryControl Unit
LanguageEnglish

Related product manuals