Assembly and Operating Instructions
Note
Varioustypesofsensorscanbeconnectedtothedevice(pleaserefer
totherelevantoperatinginstructionsforyourchosensensor).
Sun sensor (Sun sensor for sun and wind control device Centronic Sensor-
Control SC41)
Wind sensor (wind sensor for sun and wind control device Centronic Sensor-
Control SC71)
Sun and wind sensor (sun and wind sensor for sun and wind control device
Centronic SensorControl SC81)
Sensors
Explanations
Manual/Automaticslidingswitch
In the mode, only manual control commands and alarm signals are executed
(e.g.: by pressing RETRACTION, STOP, EXTENSION buttons and wind alarm).
When the sliding switch is set to “ “, automatic control commands are carried
out (e.g. Automatic sun protection function, ...)
Automaticinterruption
Automatic sun protection functions are interrupted when executing manual
travel commands (UP/STOP/DOWN). The functions are automatically reacti-
vated if either the set threshold values are exceeded/not achieved or the sliding
switch is moved from position “
“ to „ “ and then back to “ “.
Alarmsignalcontrollight
If the alarm signal control light is illuminated, this indicates an alarm signal. An
alarm signal is a continuous switching signal at the group control inputs which
lasts for more than 5 seconds.
Groupcontrol
Group control refers to the simultaneous control of several drives.