EasyManua.ls Logo

Becker RT6201 - Warning and Failure Indications

Becker RT6201
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Becker Avionics
Warning and Failure Indications
36 VHF Transceiver 0638.420-071 Issue 06 02/2021
Display Contents
Description
at intervals of 3 s
"LOW BATTERY":
The supply voltage of the transceiver is less than the
threshold adjusted in the configuration setup.
The device is operable but it can have a decreased
performance depending on supply voltage.
Possible cause:
Accumulator capacity problems
Power interrupts.
General power supply problems.
Adjustment for low battery threshold too high.
at intervals of 3 s
"STUCK PTT":
The transmit mode is automatically terminated (return to
receive mode) after 120 s of continuous transmitting.
The transceiver goes back to receive mode also if the
PTT line is still active (GND).
Possible cause:
Transmission continues more than 120 seconds.
Frequent overriding can decrease the MTBF.
PTT-key is stuck.
PTT line permanently grounded (short circuit in
installation).
Notice: For the start of a new transmission it is necessary to set the
/PTT line inactive (open).
at intervals of 3 s
"TX HOT":
"TX HOT" is shown if the internal device temperature is
> +90 °C.
Transceiver is still operable. The performance of
transmitter is decreased.
Possible cause:
Very high environmental temperature, long
transmissions times and airflow conditions are not
sufficient.
LOW BATTERY
IC
118.005
STUCK PTT
IC
1
18.005
TX HOT
IC
1
18.005

Other manuals for Becker RT6201