Maintenance:
Preventative Maintenance Schedule:
Every 40 to 200 Hours
o Check and clean air intake filter. Every 4 filter cleanings a new filter should be installed and
minimally every year.
o Blow dust and debris off outside of pump
Every 3000 Hours
o Grease bearings with pump running. Remove filter cover and place filter over direct inlet to
pump and start pump. Remove grease fitting covers and pump gun
25 times in each fitting
o Check Vanes for minimum width. Replace if necessary.
2.200/250/250SK 41mm minimum width
2.400/500 60mm minimum width
o Inspect vanes for improper wear (cupping or uneven wear). Replace if necessary.
1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Becker TLF 2.250 and is the answer not in the manual?

Becker TLF 2.250 Specifications

General IconGeneral
Frequency50/60 Hz
Housing MaterialCast iron
Voltage230 V
Impeller MaterialBronze
Connection Outlet1" BSP