Greasing
Grease Bearings Every 3000 Hours:
o Place the filter back over the non-return valve.
o Remove the plastic caps covering the grease ports.
o 25 times in each fitting
o Grease while running
Grease gun part number = 74330500000
5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Becker TLF 2.250 and is the answer not in the manual?

Becker TLF 2.250 Specifications

General IconGeneral
Frequency50/60 Hz
Housing MaterialCast iron
Voltage230 V
Impeller MaterialBronze
Connection Outlet1" BSP