4.4 Technical data - Ethernet
System data X001 Ethernet (CX8090)
Transmission medium 4 x 2 twisted pair copper cable category 5 (100
Mbaud)
Cable length 100 m from switch to CX8090
Data transfer rate 10/100 Mbaud
Topology star wiring
Protocols all non- real-time-capable protocols that are based on
TCP or UDP and require no real-time extension
System data X101/102 Ethernet (CX8090) real-time interface
Transmission medium 4 x 2 twisted pair copper cable category 5 (100
Mbaud)
Cable length 100 m from switch to CX8090
Data transfer rate 100 Mbaud
Topology Star-form cabling, line topology
Protocols (real-time) RT-Ethernet, EAP (publisher/subscriber)
Protocols (non-real-time) all non-real-time-capable protocols that are based on
TCP or UDP and require no real-time extension