Synchronisation to velocity
TS505512 Version: 1.3
Example 2:
As example 1, but with coupling factor 1.5.
(*Start parameters*)
fMasterVelo:=500;
fSlaveVelo:=-250;
(*Couplingparameters*)
fGearRatio:=1.5;
fSlaveAcc:=2500;
fSlaveDec:=2500;
fSlaveJerk:=5000;