Casting without camera
With the NAUTILUS
®
T, casting without camera
serves as an "emergency operation" in case the
camera is malfunctioning/not available.
1. Go to "Settings" > "Program".
2. Deactivate the camera.
3. Optional: Enter log data (see "Setting up the
protocol" on page 40). This data appears in the
casting protocol that is stored on the con-
nected USB flash drive.
Enter work number, batch and casting quan-
tity and confirm the entry with "OK" or
Skip the data entry with "Abort".
4. Insert the alloy.
5. Close the crucible door.
6. Confirm the preheating process with "OK".
For some alloys, the preheating process may
be skipped with a second button.
NOTICE
Please note:
Preheat precious-metal and Pd alloys with /
without crucible insert until the first alloying
components deform, but do not melt.
Preheat CoCr and NiCr alloys until the alloying
components glow bright red; the alloying com-
ponents are still solid.
Important: Do not preheat for too long as the
alloy will melt otherwise. The moment the last
solid alloying component is sinking into the melt is
important for starting the timer!

Other manuals for Bego Nautilus CC plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bego Nautilus CC plus and is the answer not in the manual?

Bego Nautilus CC plus Specifications

General IconGeneral
BrandBego
ModelNautilus CC plus
CategoryDental equipment
LanguageEnglish

Related product manuals